TA-1.6 Total Organic Carbon (TOC) Analyzer


Posted December 20, 2024 by Technovaluesolutions-123

The product uses the electrical conductivity difference detection technology,adopting the principle of ultraviolet catalytic oxidation, with high accuracy and short response time

 
Product Details

Parameters:

Power Supply
100 – 260 VAC, 50HZ, 120W

Conductivity Detection Range
0.055us/cm-8.000us/cm

Measure Range
0.001mg/L~1.0 mg/L(1~1000ppb)

Accuracy
±3%

Resolution
0.001mg/L

Analyzing Time
Continues Analyzing

Response Time
5mins

Measuring Limit
0.001 mg/L

Sample Temperature
1-99℃

Applied Range
Offline in the Laboratory、Cleaning Validation

Authority Management
User name and password login ,to meet FDA 21CFR PART 11 requirements

Print Function
External Printer

Historical Records
More then 5000 sets

Audit trail
customized

Audit trail records
≥3years

Display Screen
Color Touch Screen

Weight
8.5KG

Dimension(mm)
400*240*270



Features

◆ No need of nitrogen, oxygen, acid reagent and oxidant, so the operation is simple and the cost is low;

◆ Can be used in off-line laboratory, to meet the test and cleaning validation for organic carbon injection water and purified water;

◆ Equipped with automatic sampler, and the system suitability validation can be done automatically;

◆ It has the limit alarm design, and when the test sample exceeds the prescribed limit, the instrument makes automatic alarm;

◆ It is in conformity with the test scheme as specified in the new edition of state pharmacopoeia;

◆ Automatic lock screen in time 0-60mins, set “0” is unlock screen mode;

◆ Users quantity can add to 100 ;

◆ If the user's password is entered incorrectly for 5 times, the system will automatically freeze the user. After freezing, the system level user can change the password to unlock. When changing the password, it is necessary to change the locking state to the active state.

◆ Add user running valid date is 1-999 days

◆ When the user state is locked, the system level user can be unlocked, but the password is changed at the same time, the original password can not be used

◆ When connecting automatic sampler test or single machine offline test, it is necessary to enter the sample name, and you can enter numbers, letters, symbols, 0 ~ 16 digits.
Contact us : +91 8879330481
Email : [email protected]
Web : www.technovalue.in
Add: Plot No. 131, Sector 1A, Koparkhairane, Navi Mumbai- 400709.

Contact us : +91 8879330481
Email : [email protected]
Web : www.technovalue.in
Add: Plot No. 131, Sector 1A, Koparkhairane, Navi Mumbai- 400709.
-- END ---
Share Facebook Twitter
Print Friendly and PDF DisclaimerReport Abuse
Contact Email [email protected]
Issued By www.technovalue.in
Phone +91 8879330481
Country India
Categories Advertising , Blogging , Engineering
Last Updated December 20, 2024